: +86 137 9543 5491         : +86 137 9543 5491          : info@univerwave.cn

Welcome to this site!​Shanghai Univerwave Co.,Ltd

www.univerwave.cn 丨HV Testing

Technology  create  the  future

Let  us  work  together

MCB Trip Test UCL1994
    Publish time 2021-06-18 17:05    
MCB Trip Test UCL1994

Usage

It is suitable for rated current 5A-500A DC circuit breaker ampere-second characteristic test, and can be used for 5A-150A DC fuse ampere-second characteristic test.


Feature

n It can be used alone or online with PC.
n 9 inch color LCD, touch operation mode, high speed thermal printer.
n Power electronic control technology is adopted to generate large current output, which has fast response speed, high accuracy and continuous adjustable.
n Multiple high-precision sensors automatically switch the current range and high-performance 32-bit AD acquisition chip.
n With power off storage function, it can store 100 sets of test data.
n Optional ampere-second action test mode and current-through non-action test mode.
n When operating the instrument on a single computer, the test can be printed completely automatically, the data can be stored automatically, the data report forms and data curves can be generated without online.
n The instrument has functions of overheating, overcurrent and overvoltage protection.
n The instrument has strong anti-interference ability and electromagnetic compatibility.



Technical Indicators

n Power input: 220V± 10%, frequency: 50HZ± 0.5HZ

n Test current range: 5-500A

n Test current ripple coefficient: less than 5%;

n Stability of output current:≤ 0.5%;

n Time record: 0-9999s; Minimum time resolution: 0.001s

n The environment temperature: - 20 ℃ to 50 ℃

n Overall dimension: 470mm(length) 320mm (width) 460mm (height);

n Weight: 23kg