Cable Fault Locator Tester UCL2001
    Publish time 2021-06-18 16:46    
Cable Fault Locator Tester UCL2001

UCL2001 Cable Fault Locator

Usage

Consisting of transmitter, receiver, magnetic induction wand, location detection frame and other components.This instrument is a special instrument cable, cable fault location test for the test object which is a metal conductor (wire pairs, sheath, shield) of a variety of fiber optic cable. Its main function is to locate bad insulation test points, probe and cable depth testing cable path.

 

Feature

Higher receiving sensitivity

Lower Static drift

High positioning accuracy

Strong anti-interference capability

LCD display showing the signal and status

Charger and Built-in lithium battery for charging

 

Technical Parameters

Tracing positioning distance: telephone cable is around 3km, other cables are up to 20km

Positioning impedance range: 0-5MΩ

Positioning accuracy: <± 10cm  Depth probe: <3m



UCL2001 Cable Fault Tester

Usage

This UCL2001 Cable Fault Tester is a comprehensive set of cable fault detection equipment. It can be used to detect flash-over cable fault, the earthing of the resistance, short circuit , cable break, and poor contact,with acoustic instrument, the exact location of the fault can be accurately detected. This tester is particularly suitable for testing voltage power cables and communication cables in various models and different levels

 

Feature

Fully Featured

High precision

High intelligence

The waveform and data can be stored and tuned out

The waveform and data can be stored and tuned out

It can show the dual trace

It can compare the fault waveform with normal waveform, which is conductive to further determine the fault  

It can extended the proportional of the waveform

If the waveform proportion changed, the accurate testing can be achieved

The position of the double cursor can be changed as you like, it can show the direct distance or the relative distance of the fault point and the tested point

It can modify the transmission speed with different tested-cable

The small size makes it portable and the built-in rechargeable battery makes it easy to carry and use

 

Technical Parameters

Farthest test distance: 15Km (open wire up to 100 km)

Detection blind area : 1m

Data-reading resolution: 1m

Power dissipation : 5VA

Conditions of Use: Ambient temperature 0 ℃ ~ + 40 ℃(Limit temperature -10 ℃ ~ + 50 ℃) Relative humidity 40 ℃ (20 ~ 90)% RH Atmospheric pressure (86 ~ 106) Kpa

Volume: 275 × 220 × 160mm3

Weight: 1.8kg



Cable Fault Tester